{"id":30441,"date":"2019-05-29T14:09:37","date_gmt":"2019-05-29T03:39:37","guid":{"rendered":"https:\/\/www.solarquotes.com.au\/blog\/?p=30441"},"modified":"2019-05-29T14:09:37","modified_gmt":"2019-05-29T03:39:37","slug":"pvel-solar-inverter-scorecard","status":"publish","type":"post","link":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/","title":{"rendered":"Delta and Huawei Commercial Inverters Beat Fronius &#038; SMA In PVEL Testing"},"content":{"rendered":"<div id=\"attachment_30706\" style=\"width: 1210px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-30706\" class=\"wp-image-30706 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg\" alt=\"PVEL testing - top performing solar inverters\" width=\"1200\" height=\"628\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg 1200w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test-300x157.jpg 300w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test-768x402.jpg 768w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test-1024x536.jpg 1024w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><p id=\"caption-attachment-30706\" class=\"wp-caption-text\">And you thought the election was a shock result&#8230;<\/p><\/div>\n<p>I have good news.\u00a0 <a href=\"https:\/\/www.pvel.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">PVEL<\/a> &#8212;\u00a0 a standards testing company &#8212; has released a <a href=\"https:\/\/www.pvel.com\/inverter-scorecard\/\" target=\"_blank\" rel=\"noopener noreferrer\">solar inverter scorecard<\/a>.\u00a0 It describes how a dozen different tests were performed on a variety of inverters and which were the top performers<!--more--><\/p>\n<p>The bad news is the inverter scorecard is focused on North America and none of the top performing inverter models are available in Australia.\u00a0 Even if you got your hands on one you wouldn&#8217;t be able to use it here, as North American current is different because electrons spin counter-clockwise in the northern hemisphere.<sup class='endnote'><a href='https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#en-30441-1' id='enref-30441-1' onclick='return hhEndnotes_show(30441)'>1<\/a><\/sup>\u00a0 Also, some of the inverters that did well are too large for normal residential use.<\/p>\n<p>Another problem with the scorecard is it only shows which solar inverters were top performers and not which did badly or whether or not an inverter that wasn&#8217;t a top performer was even given a particular test.<\/p>\n<p>Despite these drawbacks I&#8217;ll describe the tests performed and which inverters did well.\u00a0 After all, if a company produces solar inverters that perform well in North America they are likely to make ones that work well Down Under.\u00a0 The brands that received the most top performer ratings were <a href=\"https:\/\/www.solarquotes.com.au\/inverters\/delta-review.html\" target=\"_blank\" rel=\"noopener noreferrer\">Delta<\/a> and <a href=\"https:\/\/www.solarquotes.com.au\/inverters\/huawei-review.html\" target=\"_blank\" rel=\"noopener noreferrer\">Huawei<\/a> and they are both available here.<\/p>\n<h2>Who The Hell Is PVEL?<\/h2>\n<p>PVEL stands for PV Evolution Labs.\u00a0 It&#8217;s probably not evolution like this:<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-30565\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/ytrFsl.gif\" alt=\"\" width=\"320\" height=\"240\" \/><\/p>\n<p>Because that&#8217;s just a cartoon.\u00a0 It&#8217;s not even biological evolution like this:<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-30566\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/diItxL.gif\" alt=\"\" width=\"720\" height=\"404\" \/><\/p>\n<p>Which is scary if you happen to know it shows <a href=\"https:\/\/www.youtube.com\/watch?v=plVk4NVIUh8\" target=\"_blank\" rel=\"noopener noreferrer\">bacteria evolving resistance<\/a> to increasing concentrations of antibiotics.<\/p>\n<p>Instead it&#8217;s about the evolution of solar technology thanks to human-guided change.<\/p>\n<p>PVEL tests solar panels, inverters, and other solar power hardware to find out what works well, what doesn&#8217;t work well, and what meets standards.\u00a0 It was part of <a href=\"https:\/\/www.dnvgl.com\/\">DVNGL<\/a>, which is a huge Norwegian standards organization.\u00a0 I wrote about their solar panel scorecards in <a href=\"https:\/\/www.solarquotes.com.au\/blog\/tests-put-phono-solar-panels-on-top-for-australians\/\">2016<\/a>, <a href=\"https:\/\/www.solarquotes.com.au\/blog\/jinko-trina-torture-test\/\">2017<\/a>, and <a href=\"https:\/\/www.solarquotes.com.au\/blog\/dnv-gl-2018-solar-panel-test\/\">2018<\/a>.\u00a0 But now PVEL has been spun off and made an independent solar testing organization.\u00a0 This could be because DVNGL is heavily involved in the oil and gas industry and they wanted to avoid a potential conflict of interest between those working to reduce greenhouse gas emissions and those who want to watch the world burn.<sup class='endnote'><a href='https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#en-30441-2' id='enref-30441-2' onclick='return hhEndnotes_show(30441)'>2<\/a><\/sup><\/p>\n<h2>Issues With Inverters<\/h2>\n<p>Inverters are the most likely to fail part of solar power systems.\u00a0 This is because:<\/p>\n<ul>\n<li>They perform many functions and so are complex.<\/li>\n<li>They contain hundreds of different components and if one fails often the whole thing does.<\/li>\n<li>They are dependent on software that can be faulty and software updates can introduce new problems.<\/li>\n<\/ul>\n<div id=\"attachment_30668\" style=\"width: 1136px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-30668\" class=\"wp-image-30668 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/just-like-me.jpg\" alt=\"inverter internals\" width=\"1126\" height=\"370\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/just-like-me.jpg 1126w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/just-like-me-300x99.jpg 300w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/just-like-me-768x252.jpg 768w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/just-like-me-1024x336.jpg 1024w\" sizes=\"(max-width: 1126px) 100vw, 1126px\" \/><p id=\"caption-attachment-30668\" class=\"wp-caption-text\">Just like me.<\/p><\/div>\n<h2>Testing Methodology<\/h2>\n<p>PVEL tested 35 inverters from 12 different manufacturers.\u00a0 While manufacturers pay to have their products tested, PVEL selects the solar inverters used for testing to make sure they are representative of what the company sells and not specially made high quality versions.<\/p>\n<p>What we&#8217;re not told is which inverters were tested and which did poorly.\u00a0 All the scorecard does is tell us which were the top performers in a test.\u00a0 If you want details on what are the dregs of the inverters they investigated you&#8217;ll have to pay PVEL for a full report and then keep it confidential and not blab about it online.<sup class='endnote'><a href='https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#en-30441-3' id='enref-30441-3' onclick='return hhEndnotes_show(30441)'>3<\/a><\/sup><\/p>\n<h2>Passive Chamber Testing<\/h2>\n<p>The first set of 3 tests is called Passive Chamber Testing.\u00a0 The inverters are shoved in a chamber and exposed to extremes of heat, cold, and humidity.\u00a0 It&#8217;s called passive because the inverters aren&#8217;t turned on.\u00a0 The goal is to test how physically tough they are and whether or not they are likely\u00a0 to withstand years of exposure to the weather.<\/p>\n<p>The 3 tests in this section were:<\/p>\n<ul>\n<li>Damp Heat:\u00a0 Temperature is held at 85 degrees and humidity at 85%<\/li>\n<li>Thermal Cycling:\u00a0 Temperature is cycled between -40 and 85 degrees<\/li>\n<li>Humidity Freeze:\u00a0 Cycled between 85 degrees and 85% humidity and -40 degrees<\/li>\n<\/ul>\n<p>We&#8217;re not told how long these tests last for or how many cycles they were run for but they do say it, &#8220;&#8230;builds and expands on the PV module IEC 61215 test standard.&#8221;\u00a0 To meet that standard the tests would need to be run for a minimum of:<\/p>\n<ul>\n<li>Damp Heat:\u00a0 85 degrees and 85% humidity for 1,000 hours (42 days)<\/li>\n<li>Thermal Cycling:\u00a0 200 cycles between -40 and 85 degrees<\/li>\n<li>Humidity Freeze:\u00a0 10 cycles between 85 degrees and 85% humidity and -40 degrees<\/li>\n<\/ul>\n<p>This is much less than what PVEL put solar panels through, but panels are expected to &#8212; hopefully &#8212; last at least 25 years, while the many solar inverters are doing well if they last more than 10 years.\u00a0 The minimum product warranty for solar panels is 10 years while the majority of inverters only have a 5 year warranty.\u00a0 Given the current expected life expectancy of solar inverters it is reasonable for PVEL to be less harsh than when testing panels.<\/p>\n<p>The two solar inverters that weathered these tests the best were the 8 kilowatt Delta M8-TL-US and the 7.7 kilowatt SMA SB7.7-ISP-US-40:<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-30621 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/passive-tests-top-performers.jpg\" alt=\"PVEL passive chamber testing - top performing inverters\" width=\"1137\" height=\"116\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/passive-tests-top-performers.jpg 1137w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/passive-tests-top-performers-300x31.jpg 300w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/passive-tests-top-performers-768x78.jpg 768w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/passive-tests-top-performers-1024x104.jpg 1024w\" sizes=\"(max-width: 1137px) 100vw, 1137px\" \/><\/p>\n<p>While these are both US models that aren&#8217;t sold here it still indicates Delta and SMA know how to make durable inverters.<\/p>\n<p>While we&#8217;re told these two solar inverters came out smelling of roses, we&#8217;re not told which ones came out smelling of ozone generated by sparks and short circuits resulting from sub-optimal construction.\u00a0 But we are given the following graph:<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-30625 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/failed-to-operate.gif\" alt=\"Inverter testing - operational and failure rates\" width=\"815\" height=\"212\" \/><\/p>\n<p>While all survived thermal cycling without having their performance seriously affected, not all came out of the Damp Heat and Humidity Freeze tests alive or unscathed.\u00a0 A significant number either failed to work or had their performance degraded.<\/p>\n<h2>Thermal Performance Test<\/h2>\n<p>While the previous tests were passive and run with the solar inverters turned off until tested, the Thermal Performance Tests use switched on inverters and consisted of the following:<\/p>\n<ul>\n<li>Powered Thermal Cycling:\u00a0 The inverter is operated while the air temperature is cycled between the manufacturer&#8217;s stated minimum and maximum operating temperatures.<\/li>\n<li>High Temperature Operation:\u00a0 The temperature is cranked up to the inverter&#8217;s maximum operating temperature and left there while it is fed current that simulates being connected to solar panels.<\/li>\n<li>Low Temperature Operation:\u00a0 The inverter is cooled to its minimum operating temperature and then operated while the air is kept at that temperature.<\/li>\n<\/ul>\n<p>These tests are done with multiple temperature sensors inside the inverter.\u00a0 If these find some electronic components get much hotter than others it indicates those components are likely to fail early.\u00a0 If the solar inverter derates and starts doing less work to prevent heat levels getting high earlier than the manufacturer says, it indicates the inverter might last but it will provide less less energy on hot days.\u00a0 PVEL describes this problem using bigger words than I did:<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-30648 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/thermal-drift.gif\" alt=\"Thermal performance and inverters\" width=\"1133\" height=\"202\" \/><\/p>\n<p>The best performers in these tests are shown in the graphic below:<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-30651 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/thermal-top-performers.gif\" alt=\"PVEL Power Thermal Cycling testing - top performing solar inverters\" width=\"1137\" height=\"154\" \/><\/p>\n<p>While the Delta, <a href=\"https:\/\/www.solarquotes.com.au\/inverters\/sma-review.html\" target=\"_blank\" rel=\"noopener noreferrer\">SMA<\/a>, and Huawei inverters could all potentially be used residentially, the <a href=\"https:\/\/www.solarquotes.com.au\/inverters\/schneider-electric-review.html\" target=\"_blank\" rel=\"noopener noreferrer\">Schneider<\/a> Conext CL-60A inverter is 63.4 kilowatts, which is far too large for any normal residential use.\u00a0 At 24 kilowatts the <a href=\"https:\/\/www.solarquotes.com.au\/inverters\/fronius-review.html\" target=\"_blank\" rel=\"noopener noreferrer\">Fronius<\/a> Symo 24.0-3 could theoretically be used as a <a href=\"https:\/\/www.solarquotes.com.au\/inverters\/\">residential solar inverter<\/a><sup class='endnote'><a href='https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#en-30441-4' id='enref-30441-4' onclick='return hhEndnotes_show(30441)'>4<\/a><\/sup>, but a bloody big roof that could support 200 or more panels would be required.<\/p>\n<h2>Performance Testing &#8212; Efficiency<\/h2>\n<p>How much energy an inverter supplies depends on its efficiency at turning <a href=\"https:\/\/www.solarquotes.com.au\/glossary.html#dc\">DC power<\/a> from solar panels into the <a href=\"https:\/\/www.solarquotes.com.au\/glossary.html#ac\">AC power<\/a> homes and grids use.\u00a0 Three tests are used to measure this:<\/p>\n<ul>\n<li>MPPT Efficiency:\u00a0 This tests how well an inverter&#8217;s <a href=\"https:\/\/www.solarquotes.com.au\/inverters\/mppt\/\">Multiple Power Point Trackers<\/a> (MPPT) can adjust to fluctuations in output from solar panels.<\/li>\n<li>Conversion Efficiency:\u00a0 This measures how efficient a solar inverter is at different power levels and averages the result.<\/li>\n<li>Energy Harvest:\u00a0 This test involves measuring how well an inverter performs through a simulated day including morning startup, full day operation, and evening shutdown.<\/li>\n<\/ul>\n<p>Top performers in these tests were:<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-30653 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/efficiency-top-performers.gif\" alt=\"PVEL performance testing - top performing solar inverters\" width=\"1138\" height=\"160\" \/><\/p>\n<p>All the Huawei inverters listed above as top performers are too large for normal household use.<\/p>\n<h2>Operational Envelope Testing<\/h2>\n<p>Despite the name, Operation Envelope Testing is nothing to do with working out what the best envelopes for operating on people are.<sup class='endnote'><a href='https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#en-30441-5' id='enref-30441-5' onclick='return hhEndnotes_show(30441)'>5<\/a><\/sup>\u00a0 It instead consists of three different tests:<\/p>\n<ul>\n<li>AC Operational Envelope:\u00a0 This tests if the inverter operates at full power while the grid AC voltage is fluctuated between the limits the manufacturer allows.<\/li>\n<li>DC Operation Envelope:\u00a0 This is similar to the AC Operation Envelope test except voltages are fluctuated on the DC power that would come from solar panels.<\/li>\n<li>Transient Response:\u00a0 This measures how well the solar inverter responds to changes in grid voltage and frequency.<\/li>\n<\/ul>\n<p>If, during these tests, an inverter derates and reduces output earlier than it should, or trips and stops operation altogether earlier than it should, then its total potential energy production will be reduced.\u00a0 The top performers on theses tests were:<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-30656 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/operational-envelope-top-performers.gif\" alt=\"PVEL operational envelope testing - top performing solar inverters\" width=\"1137\" height=\"151\" \/><\/p>\n<h2>Field Testing<\/h2>\n<p>Field testing involves putting the inverters in a field and connecting them to solar panels to see how well they perform under real life conditions.\u00a0 Two tests were performed:<\/p>\n<ul>\n<li>Ground and Arc Fault Tests:\u00a0 Lightning is an example of an electrical arc.\u00a0 While arcs in solar systems won&#8217;t be that powerful, they are still dangerous and this test measures how well inverters detect arcs and shut the system down before damage is done.<\/li>\n<li>30 Day Runtime:\u00a0 The inverter is connected to solar panels and allowed to operate for 30 days.\u00a0 They are graded on downtime, faults, and performance.<\/li>\n<\/ul>\n<p>Top performers in field testing were:<\/p>\n<h2><img decoding=\"async\" class=\"aligncenter wp-image-30670 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/field-test.jpg\" alt=\"PVEL field testing - top performing solar inverters\" width=\"1137\" height=\"160\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/field-test.jpg 1137w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/field-test-300x42.jpg 300w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/field-test-768x108.jpg 768w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/field-test-1024x144.jpg 1024w\" sizes=\"(max-width: 1137px) 100vw, 1137px\" \/><\/h2>\n<h2>Brands That Look Best Overall<\/h2>\n<p>Of the 12 brands of solar inverters tested only 5 managed to show up in the top performer results.\u00a0 If I put those brands into a chart and show which tests one of their inverters got top performer status in, it looks like this:<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-30671 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/table.gif\" alt=\"solar inverter top peformers\" width=\"1073\" height=\"470\" \/><\/p>\n<p>This makes Delta look like the top brand overall, but we can&#8217;t conclude that because we don&#8217;t know if inverters were submitted for testing where they weren&#8217;t rated as a top performer.\u00a0 Also, some tests are more important than others.\u00a0 For example, I&#8217;d rather have a solar inverter that is durable and lasts over 10 years but with only mediocre efficiency than a highly efficient one that stops working after 6 years.<\/p>\n<p>But while we can&#8217;t draw any firm conclusions, being rated as a top performer does mean the manufacturer knows how to make solar inverters that perform well in that area and this does make Delta look good.\u00a0 Huawei also comes off looking very good.\u00a0 Schneider is next, although that is not a common brand in Australia, while Fronius and SMA are both well regarded brands here.<\/p>\n<p>It is likely that PVEL will produce an inverter scorecard every year and hopefully future ones will feature versions of solar inverters sold in Australia.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>I have good news.\u00a0 PVEL &#8212;\u00a0 a standards testing company &#8212; has released a solar inverter scorecard.\u00a0 It describes how a dozen different tests were performed on a variety of inverters and which were the top performers<\/p>\n","protected":false},"author":10,"featured_media":30706,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[48],"tags":[],"class_list":["post-30441","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-solar-inverters","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Delta and Huawei Commercial Inverters Beat Fronius &amp; SMA In PVEL Test<\/title>\n<meta name=\"description\" content=\"A torture test of commercial solar inverters has given top marks to Delta and Huawei, surprisingly beating perennial Aussie favorites Fronius and SMA.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Delta and Huawei Commercial Inverters Beat Fronius &amp; SMA In PVEL Testing\" \/>\n<meta property=\"og:description\" content=\"A torture test of commercial solar inverters has given top marks to Delta and Huawei, surprisingly beating perennial Aussie favorites Fronius and SMA.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/\" \/>\n<meta property=\"og:site_name\" content=\"SolarQuotes Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/SolarQuotes\/\" \/>\n<meta property=\"article:published_time\" content=\"2019-05-29T03:39:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Ronald Brakels\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@BrakelsRonald\" \/>\n<meta name=\"twitter:site\" content=\"@solar_quotes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/\"},\"author\":{\"name\":\"Ronald Brakels\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/person\/d0ce1779b3f5cb67cb4f146732af2fc7\"},\"headline\":\"Delta and Huawei Commercial Inverters Beat Fronius &#038; SMA In PVEL Testing\",\"datePublished\":\"2019-05-29T03:39:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/\"},\"wordCount\":1852,\"commentCount\":9,\"publisher\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg\",\"articleSection\":[\"Solar Inverters\"],\"inLanguage\":\"en-AU\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/\",\"name\":\"Delta and Huawei Commercial Inverters Beat Fronius & SMA In PVEL Test\",\"isPartOf\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg\",\"datePublished\":\"2019-05-29T03:39:37+00:00\",\"description\":\"A torture test of commercial solar inverters has given top marks to Delta and Huawei, surprisingly beating perennial Aussie favorites Fronius and SMA.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#breadcrumb\"},\"inLanguage\":\"en-AU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-AU\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#primaryimage\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg\",\"contentUrl\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg\",\"width\":1200,\"height\":628,\"caption\":\"And you thought the election was a shock result...\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Blog\",\"item\":\"https:\/\/www.solarquotes.com.au\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solar Inverters\",\"item\":\"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-inverters\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Delta and Huawei Commercial Inverters Beat Fronius &#038; SMA In PVEL Testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#website\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/\",\"name\":\"SolarQuotes Blog\",\"description\":\"An independent reckoning of the Aussie solar scene\",\"publisher\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.solarquotes.com.au\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-AU\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#organization\",\"name\":\"SolarQuotes\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-AU\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/solarquotes-logo.png\",\"contentUrl\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/solarquotes-logo.png\",\"width\":592,\"height\":600,\"caption\":\"SolarQuotes\"},\"image\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/SolarQuotes\/\",\"https:\/\/x.com\/solar_quotes\",\"https:\/\/www.instagram.com\/solarquotes\/\",\"https:\/\/au.linkedin.com\/company\/solarquotes\",\"https:\/\/www.youtube.com\/user\/SolarQuotesAustralia\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/person\/d0ce1779b3f5cb67cb4f146732af2fc7\",\"name\":\"Ronald Brakels\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-AU\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/0a252c73a3af84c860d5f55cb59b33133bd5403bb5c1c065d0e8ef95252f3237?s=96&d=monsterid&r=r\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/0a252c73a3af84c860d5f55cb59b33133bd5403bb5c1c065d0e8ef95252f3237?s=96&d=monsterid&r=r\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/0a252c73a3af84c860d5f55cb59b33133bd5403bb5c1c065d0e8ef95252f3237?s=96&d=monsterid&r=r\",\"caption\":\"Ronald Brakels\"},\"description\":\"Joining SolarQuotes in 2015, Ronald has a knack for reading those tediously long documents put out by solar manufacturers and translating their contents into something consumers might find interesting. Master of heavily researched deep-dive blog posts, his relentless consumer advocacy has ruffled more than a few manufacturer's feathers over the years. Read Ronald's full bio.\",\"sameAs\":[\"https:\/\/x.com\/BrakelsRonald\"],\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/author\/ronald\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Delta and Huawei Commercial Inverters Beat Fronius & SMA In PVEL Test","description":"A torture test of commercial solar inverters has given top marks to Delta and Huawei, surprisingly beating perennial Aussie favorites Fronius and SMA.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/","og_locale":"en_US","og_type":"article","og_title":"Delta and Huawei Commercial Inverters Beat Fronius & SMA In PVEL Testing","og_description":"A torture test of commercial solar inverters has given top marks to Delta and Huawei, surprisingly beating perennial Aussie favorites Fronius and SMA.","og_url":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/","og_site_name":"SolarQuotes Blog","article_publisher":"https:\/\/www.facebook.com\/SolarQuotes\/","article_published_time":"2019-05-29T03:39:37+00:00","og_image":[{"width":1200,"height":628,"url":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg","type":"image\/jpeg"}],"author":"Ronald Brakels","twitter_card":"summary_large_image","twitter_creator":"@BrakelsRonald","twitter_site":"@solar_quotes","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#article","isPartOf":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/"},"author":{"name":"Ronald Brakels","@id":"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/person\/d0ce1779b3f5cb67cb4f146732af2fc7"},"headline":"Delta and Huawei Commercial Inverters Beat Fronius &#038; SMA In PVEL Testing","datePublished":"2019-05-29T03:39:37+00:00","mainEntityOfPage":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/"},"wordCount":1852,"commentCount":9,"publisher":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/#organization"},"image":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg","articleSection":["Solar Inverters"],"inLanguage":"en-AU","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/","url":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/","name":"Delta and Huawei Commercial Inverters Beat Fronius & SMA In PVEL Test","isPartOf":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#primaryimage"},"image":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg","datePublished":"2019-05-29T03:39:37+00:00","description":"A torture test of commercial solar inverters has given top marks to Delta and Huawei, surprisingly beating perennial Aussie favorites Fronius and SMA.","breadcrumb":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#breadcrumb"},"inLanguage":"en-AU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/"]}]},{"@type":"ImageObject","inLanguage":"en-AU","@id":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#primaryimage","url":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg","contentUrl":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg","width":1200,"height":628,"caption":"And you thought the election was a shock result..."},{"@type":"BreadcrumbList","@id":"https:\/\/www.solarquotes.com.au\/blog\/pvel-solar-inverter-scorecard\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Blog","item":"https:\/\/www.solarquotes.com.au\/blog\/"},{"@type":"ListItem","position":2,"name":"Solar Inverters","item":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-inverters\/"},{"@type":"ListItem","position":3,"name":"Delta and Huawei Commercial Inverters Beat Fronius &#038; SMA In PVEL Testing"}]},{"@type":"WebSite","@id":"https:\/\/www.solarquotes.com.au\/blog\/#website","url":"https:\/\/www.solarquotes.com.au\/blog\/","name":"SolarQuotes Blog","description":"An independent reckoning of the Aussie solar scene","publisher":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solarquotes.com.au\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-AU"},{"@type":"Organization","@id":"https:\/\/www.solarquotes.com.au\/blog\/#organization","name":"SolarQuotes","url":"https:\/\/www.solarquotes.com.au\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-AU","@id":"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/solarquotes-logo.png","contentUrl":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/solarquotes-logo.png","width":592,"height":600,"caption":"SolarQuotes"},"image":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/SolarQuotes\/","https:\/\/x.com\/solar_quotes","https:\/\/www.instagram.com\/solarquotes\/","https:\/\/au.linkedin.com\/company\/solarquotes","https:\/\/www.youtube.com\/user\/SolarQuotesAustralia"]},{"@type":"Person","@id":"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/person\/d0ce1779b3f5cb67cb4f146732af2fc7","name":"Ronald Brakels","image":{"@type":"ImageObject","inLanguage":"en-AU","@id":"https:\/\/secure.gravatar.com\/avatar\/0a252c73a3af84c860d5f55cb59b33133bd5403bb5c1c065d0e8ef95252f3237?s=96&d=monsterid&r=r","url":"https:\/\/secure.gravatar.com\/avatar\/0a252c73a3af84c860d5f55cb59b33133bd5403bb5c1c065d0e8ef95252f3237?s=96&d=monsterid&r=r","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0a252c73a3af84c860d5f55cb59b33133bd5403bb5c1c065d0e8ef95252f3237?s=96&d=monsterid&r=r","caption":"Ronald Brakels"},"description":"Joining SolarQuotes in 2015, Ronald has a knack for reading those tediously long documents put out by solar manufacturers and translating their contents into something consumers might find interesting. Master of heavily researched deep-dive blog posts, his relentless consumer advocacy has ruffled more than a few manufacturer's feathers over the years. Read Ronald's full bio.","sameAs":["https:\/\/x.com\/BrakelsRonald"],"url":"https:\/\/www.solarquotes.com.au\/blog\/author\/ronald\/"}]}},"jetpack_featured_media_url":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/pvel-inverter-test.jpg","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p2FF2s-7UZ","jetpack-related-posts":[{"id":30859,"url":"https:\/\/www.solarquotes.com.au\/blog\/solar-panel-scorecard-2019\/","url_meta":{"origin":30441,"position":0},"title":"New Solar Panel Reliability Scorecard For 2019 &#8212; GCL, JA, And Longi Do Well","author":"Ronald Brakels","date":"June 19, 2019","format":false,"excerpt":"A new Module Reliability Scorecard was published earlier this month.\u00a0 It reveals the sadistic practices of a standards organization that subjected solar panels to torturous tests so they could announce which ones came out on top.\u00a0 But while it tells us who the winners are it doesn't reveal which panels\u2026","rel":"","context":"In &quot;Solar Panels&quot;","block_context":{"text":"Solar Panels","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-panels-2\/"},"img":{"alt_text":"PVEL solar panel scorecard - June 2019","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/06\/pvel-2019-scorecard.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/06\/pvel-2019-scorecard.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/06\/pvel-2019-scorecard.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/06\/pvel-2019-scorecard.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/06\/pvel-2019-scorecard.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":40194,"url":"https:\/\/www.solarquotes.com.au\/blog\/2020-panel-reliability-scorecard\/","url_meta":{"origin":30441,"position":1},"title":"2020 PV Reliability Scorecard: Astronergy, Canadian, Longi &#038; REC Do Well","author":"Ronald Brakels","date":"June 10, 2020","format":false,"excerpt":"PV Evolution Labs, or PVEL for short, has published their 2020 PV Module Reliability Scorecard.\u00a0 This annual report reveals the Top Performers from their latest round of solar panel testing.\u00a0 The information given is limited.\u00a0 We're only told which panels suffered little deterioration from testing. PVEL do not reveal which\u2026","rel":"","context":"In &quot;Solar Panels&quot;","block_context":{"text":"Solar Panels","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-panels-2\/"},"img":{"alt_text":"peel 2020 pv module reliability scorecard","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2020\/06\/2020-reliability-scorecard.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2020\/06\/2020-reliability-scorecard.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2020\/06\/2020-reliability-scorecard.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2020\/06\/2020-reliability-scorecard.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2020\/06\/2020-reliability-scorecard.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":62133,"url":"https:\/\/www.solarquotes.com.au\/blog\/pvel-2022-panel-scorecard\/","url_meta":{"origin":30441,"position":2},"title":"Torture Testing Reveals Modern Solar Panels Are Tougher Than Ever","author":"Ronald Brakels","date":"May 30, 2022","format":false,"excerpt":"PVEL 2022 PV Module Reliability Scorecard -- More Panels Pass All 5 Main Tests Than Ever Before. PVEL stands for PV Evolution Labs.\u00a0 Their speciality is torturing solar panels to determine how tough they are.\u00a0 Every year they publish a report that separates Top Performing panels from those they don't\u2026","rel":"","context":"In &quot;Solar Panels&quot;","block_context":{"text":"Solar Panels","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-panels-2\/"},"img":{"alt_text":"PVEL 2022 PV Module Reliability Scorecard","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/05\/2022-pvel.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/05\/2022-pvel.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/05\/2022-pvel.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/05\/2022-pvel.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/05\/2022-pvel.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":30846,"url":"https:\/\/www.solarquotes.com.au\/blog\/vodcast-episode-18-mb1080\/","url_meta":{"origin":30441,"position":3},"title":"SolarQuotes Vodcast Episode 18 \u2013\u00a0 Shonky Solar And Tortured Inverters","author":"Michael Bloch","date":"June 4, 2019","format":false,"excerpt":"Episode 18 sees Finn and Ronald discussing the ABC's recent 7.30 report on solar in Australia, new features on SolarQuotes' installer reviews pages, inverter torture testing results and more. 0:36 - Finn congratulates his nephew on his performance in the Scripps National Spelling Bee (USA), who achieved 35th out of\u2026","rel":"","context":"In &quot;General Solar &amp; Storage News&quot;","block_context":{"text":"General Solar &amp; Storage News","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-battery-news\/"},"img":{"alt_text":"SolarQuotes vodcast episode 18","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/06\/vodcast-18.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/06\/vodcast-18.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/06\/vodcast-18.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/06\/vodcast-18.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/06\/vodcast-18.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1204,"url":"https:\/\/www.solarquotes.com.au\/blog\/sungrow-inverter-beats-sma-in-latest-inverter-testing\/","url_meta":{"origin":30441,"position":4},"title":"SunGrow Inverter beats SMA in Latest Inverter Reviews","author":"Finn Peacock","date":"March 15, 2012","format":false,"excerpt":"Note: This post is just one opinion on Sungrow Inverters. Click here\u00a0for lots of Customer Reviews of Sungrow Inverters to see how they have performed in Australian homes over the last few years. If you are considering buying a Sungrow Inverter over an SMA inverter - then you should also\u2026","rel":"","context":"In &quot;Solar Inverters&quot;","block_context":{"text":"Solar Inverters","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-inverters\/"},"img":{"alt_text":"sungrow and sma inverter","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2012\/03\/sungrow-inverter-vs-sma.jpg?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":22044,"url":"https:\/\/www.solarquotes.com.au\/blog\/jfy-solar-inverter-fail-mb0613\/","url_meta":{"origin":30441,"position":5},"title":"JFY Solar Inverter Fails CEC Testing (Again)","author":"Michael Bloch","date":"June 5, 2018","format":false,"excerpt":"The JFY solar inverter saga continues, with latest testing performed by the Clean Energy Council at the manufacturer's request resulting in another failure. Just to recap, back in February we reported a Shenzhen JingFuYuan Tech Co Ltd (JFY) inverter model (Sunleaf 3000TL) failed Clean Energy Council testing against AS 4777-2\u2026","rel":"","context":"In &quot;General Solar &amp; Storage News&quot;","block_context":{"text":"General Solar &amp; Storage News","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-battery-news\/"},"img":{"alt_text":"JFY inverter fails CEC re-testing","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2018\/06\/jfy-inverter-fail.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2018\/06\/jfy-inverter-fail.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2018\/06\/jfy-inverter-fail.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2018\/06\/jfy-inverter-fail.png?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/posts\/30441","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/comments?post=30441"}],"version-history":[{"count":81,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/posts\/30441\/revisions"}],"predecessor-version":[{"id":30730,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/posts\/30441\/revisions\/30730"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/media\/30706"}],"wp:attachment":[{"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/media?parent=30441"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/categories?post=30441"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/tags?post=30441"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}