{"id":82554,"date":"2024-04-08T08:15:55","date_gmt":"2024-04-07T22:45:55","guid":{"rendered":"https:\/\/www.solarquotes.com.au\/blog\/?p=82554"},"modified":"2024-04-15T09:30:59","modified_gmt":"2024-04-15T00:00:59","slug":"bad-roof-flashings","status":"publish","type":"post","link":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/","title":{"rendered":"Failed Flashings: When Solar Roof Penetrations Go Wrong"},"content":{"rendered":"<p><img decoding=\"async\" class=\"aligncenter wp-image-82579 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg\" alt=\"roof flashings\" width=\"1200\" height=\"630\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg 1200w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header-300x158.jpg 300w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header-1024x538.jpg 1024w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header-768x403.jpg 768w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<p>Think about the tin roof over your head. Its primary function is to keep the rain out. Now picture putting holes in that tin sheet for a fat bundle of cables. It&#8217;s risky if not handled properly.<!--more--><\/p>\n<p>The weakest point of any solar installation is where the wiring enters the building. Wiring penetrations are a craft all of their own but some examples I&#8217;ve photographed are laughable. Join me as we have a giggle and learn about the worst ways of running wiring into an iron roof.<\/p>\n<p>As an automotive tradesman working to a hair&#8217;s breadth tolerance, \u00adI&#8217;ve always marvelled at how houses stand up despite what builders do to them.<\/p>\n<p>As a licenced builder, supervisor and roof plumber, I was impressed that electricians created so few leaks. I suppose it&#8217;s their one failing; despite being smarter, faster, slimmer, &amp; better looking than plumbers, some sparkies don&#8217;t understand plumbing well enough to keep ceilings or even electrical things dry.<\/p>\n<h2>Silicone Is The Savior<\/h2>\n<p>I lament the vast bulk of trades have no clue about how my old boss used nails, flux, and solder to fix roofs.<\/p>\n<p>These days, with a caulking gun and tube of &#8220;No More Skills&#8221; nothing has to fit properly because modern sealants cover a multitude of sins.<\/p>\n<p>I&#8217;m not saying we need to revive the art of sealing things with molten metal, but it wouldn&#8217;t hurt if people understood the beauty of simplicity, before designing a box gutter.<\/p>\n<h2>Follow The Roofers&#8217; Mantra: Put The Hole In The Best Place<\/h2>\n<p>It&#8217;s so simple when you apply thought, yet some trades can work for years before running into a pedant like me who&#8217;ll demonstrate precisely how it&#8217;s done.<\/p>\n<blockquote><p><strong>Imagine you&#8217;re poised to pierce a pristine roof with a huge holesaw. <\/strong><\/p>\n<p><strong>Stop and think: w<\/strong><strong>ould water trickle, or pour straight through if you forgot to put sealant on it after smoko?<\/strong><\/p><\/blockquote>\n<p>This example below really tested my patience. The conduit is placed correctly in the high flute, but the 4 screws in the down flute are not mechanically waterproof.<\/p>\n<div id=\"attachment_81969\" style=\"width: 836px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-81969\" class=\"wp-image-81969 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/02\/bad-new-flashing-1.jpg\" alt=\"Badly installed roof flashing\" width=\"826\" height=\"525\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/02\/bad-new-flashing-1.jpg 826w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/02\/bad-new-flashing-1-300x191.jpg 300w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/02\/bad-new-flashing-1-768x488.jpg 768w\" sizes=\"(max-width: 826px) 100vw, 826px\" \/><p id=\"caption-attachment-81969\" class=\"wp-caption-text\">How to <strong>ruin<\/strong> a new roof. Drive screws through the low part of the profile where the water runs straight over them.<\/p><\/div>\n<h2>Holesaws Shed Hot Shavings &amp; Rust Roofs<\/h2>\n<p>A toothed blade makes an awful racket as you tear through a 0.4mm metal sheet. The noise makes me wince, especially when I know the drill operator has no mechanical sympathy and no cutting oil on the blade either.<\/p>\n<p>Careless sprinkling of hot swarf on colourbond painted surfaces means speckles of rust appear in just days. This coastal installation shows why roofing contractors can rightly demand sheets be replaced on new buildings; cleaning up once you&#8217;ve made the hole is essential.<\/p>\n<div id=\"attachment_82569\" style=\"width: 513px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82569\" class=\"wp-image-82569 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-rusty-swarf.jpg\" alt=\"wiring through roof flashing going rusty\" width=\"503\" height=\"900\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-rusty-swarf.jpg 503w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-rusty-swarf-168x300.jpg 168w\" sizes=\"(max-width: 503px) 100vw, 503px\" \/><p id=\"caption-attachment-82569\" class=\"wp-caption-text\">The aggressive environment explains why using a flashing without screws makes sense. If only it had been blown\/swept\/wiped up properly, the roof would not be rusty.<\/p><\/div>\n<p>This conduit was already sealed, so the flashing is a bit decorative but still badly fitted.<\/p>\n<div id=\"attachment_82556\" style=\"width: 535px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82556\" class=\"wp-image-82556 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-with-rusty-swarf.jpg\" alt=\"\" width=\"525\" height=\"753\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-with-rusty-swarf.jpg 525w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-with-rusty-swarf-209x300.jpg 209w\" sizes=\"(max-width: 525px) 100vw, 525px\" \/><p id=\"caption-attachment-82556\" class=\"wp-caption-text\">Stainless screws and smudges of silicone are ok, but gaps that trap moisture and rusty swarf etching into a spanking new roof aren&#8217;t<\/p><\/div>\n<p>Fast forward a few years, where failing to finish\/feather the edges of the silicone means it doesn&#8217;t adhere properly, then water seeps underneath.<\/p>\n<div id=\"attachment_82558\" style=\"width: 487px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82558\" class=\"wp-image-82558 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-badly-aged-1.jpg\" alt=\"old roof flashing removed to show a leak\" width=\"477\" height=\"900\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-badly-aged-1.jpg 477w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-badly-aged-1-159x300.jpg 159w\" sizes=\"(max-width: 477px) 100vw, 477px\" \/><p id=\"caption-attachment-82558\" class=\"wp-caption-text\">Moisture has crept under the edge.<\/p><\/div>\n<h2>Some People Don&#8217;t Deserve Roofs<\/h2>\n<p>Flashings should allow water to pass, but having lined them up <em>across<\/em> the pan, this numpty&#8217;s created a dam to hold water.<\/p>\n<div id=\"attachment_82565\" style=\"width: 569px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82565\" class=\"wp-image-82565 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/decktite-deck-roof-bad.jpg\" alt=\"wiring badly installed through the roof\" width=\"559\" height=\"900\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/decktite-deck-roof-bad.jpg 559w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/decktite-deck-roof-bad-186x300.jpg 186w\" sizes=\"(max-width: 559px) 100vw, 559px\" \/><p id=\"caption-attachment-82565\" class=\"wp-caption-text\">Blue shading shows side-by-side penetrations create a pool on the roof.<\/p><\/div>\n<p>Of course, things could be worse; overlapping flashings that birds subsequently ate are another liability.<\/p>\n<div id=\"attachment_82568\" style=\"width: 589px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82568\" class=\"wp-image-82568 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-overlapped-damaged.jpg\" alt=\"two electrical conduits through a roof\" width=\"579\" height=\"525\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-overlapped-damaged.jpg 579w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-overlapped-damaged-300x272.jpg 300w\" sizes=\"(max-width: 579px) 100vw, 579px\" \/><p id=\"caption-attachment-82568\" class=\"wp-caption-text\">Galahs and Corellas chewed everything off this job.<\/p><\/div>\n<h2>Other Obstacles Can Force Your Hand<\/h2>\n<p>This image shows whacking a holesaw through where a pilot hole would do can lead to unitended damage. Nursing homes full of firewalls mean you don&#8217;t always have a choice, but I always try to measure or dent the surface to check from the opposite side, before piercing the roof.<\/p>\n<div id=\"attachment_82580\" style=\"width: 696px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82580\" class=\"wp-image-82580 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-overlapped-firewall.jpg\" alt=\"holes in the roof for solar wiring\" width=\"686\" height=\"525\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-overlapped-firewall.jpg 686w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-overlapped-firewall-300x230.jpg 300w\" sizes=\"(max-width: 686px) 100vw, 686px\" \/><p id=\"caption-attachment-82580\" class=\"wp-caption-text\">A hole punched through the wrong side of a firewall is bogged up, and more holes end up too close together.<\/p><\/div>\n<h2>Roofers Can Have A Different Approach<\/h2>\n<p>When this house had new cladding installed, the roof plumber made holes and pulled the existing solar wiring conduits through to seal them himself. Years ago, I used this method without issue. In reality, this won&#8217;t leak, but it doesn&#8217;t meet solar standards, so we put a flashing over it anyway.<\/p>\n<div id=\"attachment_82567\" style=\"width: 535px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82567\" class=\"wp-image-82567 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/double-conduit-through-roof.jpg\" alt=\"two electrical conduits exiting roof\" width=\"525\" height=\"698\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/double-conduit-through-roof.jpg 525w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/double-conduit-through-roof-226x300.jpg 226w\" sizes=\"(max-width: 525px) 100vw, 525px\" \/><p id=\"caption-attachment-82567\" class=\"wp-caption-text\">Two existing conduits sealed with urethane by a qualified trade during re-roofing<\/p><\/div>\n<h2>Shedding Water Should Be Second Nature<\/h2>\n<p>While it&#8217;s less likely on steeper pitches, these shaded areas show how water is often held up behind flashings. It&#8217;s a needless opportunity to start corrosion, mould and leaks.<\/p>\n<div id=\"attachment_82566\" style=\"width: 535px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82566\" class=\"wp-image-82566 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-water-pooling.jpeg\" alt=\"wiring coming from a roof under solar panels\" width=\"525\" height=\"506\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-water-pooling.jpeg 525w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-water-pooling-300x289.jpeg 300w\" sizes=\"(max-width: 525px) 100vw, 525px\" \/><p id=\"caption-attachment-82566\" class=\"wp-caption-text\">Plenty of silicone used, which exacerbates water pooling on lower pitched roofs<\/p><\/div>\n<div id=\"attachment_82617\" style=\"width: 535px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82617\" class=\"wp-image-82617 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-double-crap.jpg\" alt=\"bad wiring on a roof\" width=\"525\" height=\"660\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-double-crap.jpg 525w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-double-crap-239x300.jpg 239w\" sizes=\"(max-width: 525px) 100vw, 525px\" \/><p id=\"caption-attachment-82617\" class=\"wp-caption-text\">Blue shading to highlight where water pools &amp; dirt collects. Badly placed screws but at least it&#8217;s all sealed with silicone. Bonus crap electrical practice with unglued couplings too.<\/p><\/div>\n<h2>Even Plumbers Make Mistakes<\/h2>\n<p>This &#8220;stink pipe&#8221; has been nicely flashed with pop rivets to secure the dektite. Four holes in the bottom of the channel will hold the rubber down nice and tight, but it&#8217;s still the wrong method.<\/p>\n<p>Water leaks <em>through<\/em> rivets easily if they&#8217;re tubular ones. Best practice is to use blind rivets and cover them with silicone to prevent corrosion attacking them anyway.<\/p>\n<div id=\"attachment_82571\" style=\"width: 535px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82571\" class=\"wp-image-82571 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-stink-pipe.jpg\" alt=\"plumbing vent through a corrugated roof\" width=\"525\" height=\"605\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-stink-pipe.jpg 525w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-stink-pipe-260x300.jpg 260w\" sizes=\"(max-width: 525px) 100vw, 525px\" \/><p id=\"caption-attachment-82571\" class=\"wp-caption-text\">40mm plumbing vent with mud showing exactly where the water pools and then runs across the flashing<\/p><\/div>\n<h2>Finding Leaks Is A Challenge<\/h2>\n<p>Unprotected from the western sun, this badly executed shit show of overlapped flashings was the suspected source for a water leak. To diagnose it, we troweled a whole tube of silicone in, simply to displace any water that might sit on top.<\/p>\n<p>Ultimately, warranty obligations saw the entire 100kW array removed, reframed and reinstalled, so the wiring got a once over and this rubbish was repaired with a metal patch.<\/p>\n<div id=\"attachment_82572\" style=\"width: 562px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-82572\" class=\"wp-image-82572 size-full\" src=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-overlapped-bogged.jpg\" alt=\"badly sealed wiring through a roof\" width=\"552\" height=\"800\" srcset=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-overlapped-bogged.jpg 552w, https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-overlapped-bogged-207x300.jpg 207w\" sizes=\"(max-width: 552px) 100vw, 552px\" \/><p id=\"caption-attachment-82572\" class=\"wp-caption-text\">Eventually the scab was ripped off to make proper repairs.<\/p><\/div>\n<h2>Don&#8217;t Despair: Most Roof Penetrations Are Fine<\/h2>\n<p>It took years to gather all these examples. Even the terrible mess shown above didn&#8217;t leak water when we examined the entrails.<\/p>\n<p>If your roof looks depressingly similar, then tune in next week. <a href=\"https:\/\/www.solarquotes.com.au\/blog\/good-solar-flashings\/\">I&#8217;ll show you the best tips and tricks to make durable watertight penetrations in the roof.<\/a><\/p>\n<p>There will be contrasting pictures and step-by-step guides you can show the people working on your house as an example of best practice.<\/p>\n<p>It&#8217;s almost as exciting as <a href=\"https:\/\/www.solarquotes.com.au\/blog\/solar-cable-conduit-roof\/\">writing about conduit!<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Think about the tin roof over your head. Its primary function is to keep the rain out. Now picture putting holes in that tin sheet for a fat bundle of cables. It&#8217;s risky if not handled properly.<\/p>\n","protected":false},"author":28,"featured_media":82579,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[57],"tags":[],"class_list":["post-82554","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-solar-installation","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Failed Flashings: When Solar Roof Penetrations Go Wrong<\/title>\n<meta name=\"description\" content=\"Nailing It? More Like Failing It; Here&#039;s Our Rogues Gallery Of All Too Common Mistakes When Putting Solar Wiring Through Your Roof\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Failed Flashings: When Solar Roof Penetrations Go Wrong\" \/>\n<meta property=\"og:description\" content=\"Nailing It? More Like Failing It; Here&#039;s Our Rogues Gallery Of All Too Common Mistakes When Putting Solar Wiring Through Your Roof\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/\" \/>\n<meta property=\"og:site_name\" content=\"SolarQuotes Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/SolarQuotes\/\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-07T22:45:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-04-15T00:00:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Anthony Bennett\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@solar_quotes\" \/>\n<meta name=\"twitter:site\" content=\"@solar_quotes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/\"},\"author\":{\"name\":\"Anthony Bennett\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/person\/eda68c24a3d87f41fa51e57c03d2ac2d\"},\"headline\":\"Failed Flashings: When Solar Roof Penetrations Go Wrong\",\"datePublished\":\"2024-04-07T22:45:55+00:00\",\"dateModified\":\"2024-04-15T00:00:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/\"},\"wordCount\":1207,\"commentCount\":7,\"publisher\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg\",\"articleSection\":[\"Solar Installation\"],\"inLanguage\":\"en-AU\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/\",\"name\":\"Failed Flashings: When Solar Roof Penetrations Go Wrong\",\"isPartOf\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg\",\"datePublished\":\"2024-04-07T22:45:55+00:00\",\"dateModified\":\"2024-04-15T00:00:59+00:00\",\"description\":\"Nailing It? More Like Failing It; Here's Our Rogues Gallery Of All Too Common Mistakes When Putting Solar Wiring Through Your Roof\",\"breadcrumb\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#breadcrumb\"},\"inLanguage\":\"en-AU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-AU\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#primaryimage\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg\",\"contentUrl\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg\",\"width\":1200,\"height\":630},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Blog\",\"item\":\"https:\/\/www.solarquotes.com.au\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solar Installation\",\"item\":\"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-installation\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Failed Flashings: When Solar Roof Penetrations Go Wrong\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#website\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/\",\"name\":\"SolarQuotes Blog\",\"description\":\"An independent reckoning of the Aussie solar scene\",\"publisher\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.solarquotes.com.au\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-AU\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#organization\",\"name\":\"SolarQuotes\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-AU\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/solarquotes-logo.png\",\"contentUrl\":\"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/solarquotes-logo.png\",\"width\":592,\"height\":600,\"caption\":\"SolarQuotes\"},\"image\":{\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/SolarQuotes\/\",\"https:\/\/x.com\/solar_quotes\",\"https:\/\/www.instagram.com\/solarquotes\/\",\"https:\/\/au.linkedin.com\/company\/solarquotes\",\"https:\/\/www.youtube.com\/user\/SolarQuotesAustralia\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/person\/eda68c24a3d87f41fa51e57c03d2ac2d\",\"name\":\"Anthony Bennett\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-AU\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/da02d496ba89ce6576480e42da6ad36ea79ea5c1c51d5f7ce5a07774d06a1fb7?s=96&d=monsterid&r=r\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/da02d496ba89ce6576480e42da6ad36ea79ea5c1c51d5f7ce5a07774d06a1fb7?s=96&d=monsterid&r=r\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/da02d496ba89ce6576480e42da6ad36ea79ea5c1c51d5f7ce5a07774d06a1fb7?s=96&d=monsterid&r=r\",\"caption\":\"Anthony Bennett\"},\"description\":\"Anthony joined the SolarQuotes team in 2022. He\u2019s a licensed electrician, builder, roofer and solar installer who for 14 years did jobs all over SA - residential, commercial, on-grid and off-grid. A true enthusiast with a skillset the typical solar installer might not have, his blogs are typically deep dives that draw on his decades of experience in the industry to educate and entertain. Read Anthony's full bio.\",\"url\":\"https:\/\/www.solarquotes.com.au\/blog\/author\/anthony\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Failed Flashings: When Solar Roof Penetrations Go Wrong","description":"Nailing It? More Like Failing It; Here's Our Rogues Gallery Of All Too Common Mistakes When Putting Solar Wiring Through Your Roof","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/","og_locale":"en_US","og_type":"article","og_title":"Failed Flashings: When Solar Roof Penetrations Go Wrong","og_description":"Nailing It? More Like Failing It; Here's Our Rogues Gallery Of All Too Common Mistakes When Putting Solar Wiring Through Your Roof","og_url":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/","og_site_name":"SolarQuotes Blog","article_publisher":"https:\/\/www.facebook.com\/SolarQuotes\/","article_published_time":"2024-04-07T22:45:55+00:00","article_modified_time":"2024-04-15T00:00:59+00:00","og_image":[{"width":1200,"height":630,"url":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg","type":"image\/jpeg"}],"author":"Anthony Bennett","twitter_card":"summary_large_image","twitter_creator":"@solar_quotes","twitter_site":"@solar_quotes","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#article","isPartOf":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/"},"author":{"name":"Anthony Bennett","@id":"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/person\/eda68c24a3d87f41fa51e57c03d2ac2d"},"headline":"Failed Flashings: When Solar Roof Penetrations Go Wrong","datePublished":"2024-04-07T22:45:55+00:00","dateModified":"2024-04-15T00:00:59+00:00","mainEntityOfPage":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/"},"wordCount":1207,"commentCount":7,"publisher":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/#organization"},"image":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg","articleSection":["Solar Installation"],"inLanguage":"en-AU","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/","url":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/","name":"Failed Flashings: When Solar Roof Penetrations Go Wrong","isPartOf":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#primaryimage"},"image":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg","datePublished":"2024-04-07T22:45:55+00:00","dateModified":"2024-04-15T00:00:59+00:00","description":"Nailing It? More Like Failing It; Here's Our Rogues Gallery Of All Too Common Mistakes When Putting Solar Wiring Through Your Roof","breadcrumb":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#breadcrumb"},"inLanguage":"en-AU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/"]}]},{"@type":"ImageObject","inLanguage":"en-AU","@id":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#primaryimage","url":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg","contentUrl":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg","width":1200,"height":630},{"@type":"BreadcrumbList","@id":"https:\/\/www.solarquotes.com.au\/blog\/bad-roof-flashings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Blog","item":"https:\/\/www.solarquotes.com.au\/blog\/"},{"@type":"ListItem","position":2,"name":"Solar Installation","item":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-installation\/"},{"@type":"ListItem","position":3,"name":"Failed Flashings: When Solar Roof Penetrations Go Wrong"}]},{"@type":"WebSite","@id":"https:\/\/www.solarquotes.com.au\/blog\/#website","url":"https:\/\/www.solarquotes.com.au\/blog\/","name":"SolarQuotes Blog","description":"An independent reckoning of the Aussie solar scene","publisher":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solarquotes.com.au\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-AU"},{"@type":"Organization","@id":"https:\/\/www.solarquotes.com.au\/blog\/#organization","name":"SolarQuotes","url":"https:\/\/www.solarquotes.com.au\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-AU","@id":"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/solarquotes-logo.png","contentUrl":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2019\/05\/solarquotes-logo.png","width":592,"height":600,"caption":"SolarQuotes"},"image":{"@id":"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/SolarQuotes\/","https:\/\/x.com\/solar_quotes","https:\/\/www.instagram.com\/solarquotes\/","https:\/\/au.linkedin.com\/company\/solarquotes","https:\/\/www.youtube.com\/user\/SolarQuotesAustralia"]},{"@type":"Person","@id":"https:\/\/www.solarquotes.com.au\/blog\/#\/schema\/person\/eda68c24a3d87f41fa51e57c03d2ac2d","name":"Anthony Bennett","image":{"@type":"ImageObject","inLanguage":"en-AU","@id":"https:\/\/secure.gravatar.com\/avatar\/da02d496ba89ce6576480e42da6ad36ea79ea5c1c51d5f7ce5a07774d06a1fb7?s=96&d=monsterid&r=r","url":"https:\/\/secure.gravatar.com\/avatar\/da02d496ba89ce6576480e42da6ad36ea79ea5c1c51d5f7ce5a07774d06a1fb7?s=96&d=monsterid&r=r","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/da02d496ba89ce6576480e42da6ad36ea79ea5c1c51d5f7ce5a07774d06a1fb7?s=96&d=monsterid&r=r","caption":"Anthony Bennett"},"description":"Anthony joined the SolarQuotes team in 2022. He\u2019s a licensed electrician, builder, roofer and solar installer who for 14 years did jobs all over SA - residential, commercial, on-grid and off-grid. A true enthusiast with a skillset the typical solar installer might not have, his blogs are typically deep dives that draw on his decades of experience in the industry to educate and entertain. Read Anthony's full bio.","url":"https:\/\/www.solarquotes.com.au\/blog\/author\/anthony\/"}]}},"jetpack_featured_media_url":"https:\/\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header.jpg","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p2FF2s-ltw","jetpack-related-posts":[{"id":62807,"url":"https:\/\/www.solarquotes.com.au\/blog\/solar-cable-conduit-roof\/","url_meta":{"origin":82554,"position":0},"title":"The Ugly Truth About Conduit And Solar Panels","author":"Anthony Bennett","date":"July 5, 2022","format":false,"excerpt":"Protective electrical conduit is a small part of every solar install, but using it properly can make or break both the compliance and the aesthetics of that job. This post will explore the use of cable conduit in and on a solar roof. Conduit In The Roof Since 2014, DC\u2026","rel":"","context":"In &quot;Solar Installation&quot;","block_context":{"text":"Solar Installation","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-installation\/"},"img":{"alt_text":"Solar installations - conduit on roof","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/06\/corry-monster.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/06\/corry-monster.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/06\/corry-monster.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/06\/corry-monster.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/06\/corry-monster.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":95325,"url":"https:\/\/www.solarquotes.com.au\/blog\/sloppy-conduits-in-roof\/","url_meta":{"origin":82554,"position":1},"title":"Poorly Protected Wires Risk A Disaster In Your Roof","author":"Anthony Bennett","date":"October 27, 2025","format":false,"excerpt":"Electrical conduits are the tubes used to protect and route wiring. Get them wrong and you'll make roof spaces even more unsafe than they already are. So what does good conduit work look like? Read on while we peek above the manhole. Why Is Electrical Conduit Work Important? Conduit work\u2026","rel":"","context":"In &quot;Solar Installation&quot;","block_context":{"text":"Solar Installation","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-installation\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2025\/10\/Conduit-roof-space-header.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2025\/10\/Conduit-roof-space-header.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2025\/10\/Conduit-roof-space-header.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2025\/10\/Conduit-roof-space-header.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2025\/10\/Conduit-roof-space-header.jpeg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":70742,"url":"https:\/\/www.solarquotes.com.au\/blog\/installing-solar-tiled-roof\/","url_meta":{"origin":82554,"position":2},"title":"Installing Solar On A Tiled Roof? Why You Need Spare Roof Tiles","author":"Anthony Bennett","date":"March 9, 2023","format":false,"excerpt":"As a qualified builder and roofer, I should disclose that I really don't like tile roofs. They're heavy, they're porous and get heavier as they soak up water, they leak heat and dirt, they're hard to install on, and sadly, as many people find out, water leaks lead to recriminations.\u2026","rel":"","context":"In &quot;Solar Installation&quot;","block_context":{"text":"Solar Installation","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-installation\/"},"img":{"alt_text":"Installing solar panels on a tiled roof","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2023\/02\/gumtree-tiles-upper-frame.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2023\/02\/gumtree-tiles-upper-frame.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2023\/02\/gumtree-tiles-upper-frame.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2023\/02\/gumtree-tiles-upper-frame.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2023\/02\/gumtree-tiles-upper-frame.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":68088,"url":"https:\/\/www.solarquotes.com.au\/blog\/solar-raked-ceilings\/","url_meta":{"origin":82554,"position":3},"title":"Installing Solar Panels with Raked Ceilings: Challenges and Solutions","author":"Anthony Bennett","date":"January 12, 2023","format":false,"excerpt":"They say that happiness is directly proportional to ceiling height. Having grown up in a substantial c.1875 stone house, with ceilings closer to 4 metres than the standard suburban 2.4 metres, I can attest to the extra space offering some comfort - even if it's just lower temperatures during hot\u2026","rel":"","context":"In &quot;Solar Installation&quot;","block_context":{"text":"Solar Installation","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-installation\/"},"img":{"alt_text":"Solar panels and raked ceilings","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2023\/01\/raked-ceiling.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2023\/01\/raked-ceiling.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2023\/01\/raked-ceiling.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2023\/01\/raked-ceiling.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2023\/01\/raked-ceiling.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":82619,"url":"https:\/\/www.solarquotes.com.au\/blog\/good-solar-flashings\/","url_meta":{"origin":82554,"position":4},"title":"Good Flashings For Solar; Holes In Your Roof Made Waterproof","author":"Anthony Bennett","date":"April 15, 2024","format":false,"excerpt":"There are many ways to make a weatherproof cable entry to your iron roof, but as far as I\u2019m concerned, all of them except one are wrong. In this post, I\u2019ll explain what 20 years of roofing experience has taught me about making the perfect wiring penetration. It's quite simple\u2026","rel":"","context":"In &quot;Solar Installation&quot;","block_context":{"text":"Solar Installation","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-installation\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header-anaconda.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header-anaconda.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header-anaconda.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header-anaconda.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2024\/04\/dektite-header-anaconda.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":64068,"url":"https:\/\/www.solarquotes.com.au\/blog\/challenging-solar-installation\/","url_meta":{"origin":82554,"position":5},"title":"The Most Challenging Solar Installation I Ever Did","author":"Anthony Bennett","date":"August 11, 2022","format":false,"excerpt":"(trigger warning for solar nerds - this story has a very sad ending) Finn asked me to write a post on the worst solar installation I ever had to do. The worst? Ah, let me count the ways I could interpret that\u2026 this could become a series. To pick one\u2026","rel":"","context":"In &quot;Solar Installation&quot;","block_context":{"text":"Solar Installation","link":"https:\/\/www.solarquotes.com.au\/blog\/category\/solar-installation\/"},"img":{"alt_text":"A very challenging solar power system installation","src":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/08\/tough-install.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/08\/tough-install.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/08\/tough-install.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/08\/tough-install.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.solarquotes.com.au\/blog\/wp-content\/uploads\/2022\/08\/tough-install.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/posts\/82554","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/users\/28"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/comments?post=82554"}],"version-history":[{"count":15,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/posts\/82554\/revisions"}],"predecessor-version":[{"id":82990,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/posts\/82554\/revisions\/82990"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/media\/82579"}],"wp:attachment":[{"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/media?parent=82554"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/categories?post=82554"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solarquotes.com.au\/blog\/wp-json\/wp\/v2\/tags?post=82554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}