Warning From FRNSW On Solar Power System Safety 

Solar power system fires - FRNSW

Image: FRNSW

Fire and Rescue NSW has sounded a new warning after another solar PV related incident in the state.

The Camden Advertiser reports FRNSW responded to a call on Wednesday morning after smoke was reported “coming from a switch” (assumed isolator switch) connected to solar panels on the rooftop of a home in the Sydney suburb of Ingleburn.

However, it then goes on to state smoke was coming from an “inverter in the roof”, which would be a really, really bad place to install an inverter. If it was *on* the roof, that could mean a microinverter. While it’s more difficult for a microinverter-based solar power system to catch fire, it’s not impossible. But the Advertiser also states the switches for the panels and “the inverter” were then turned off by FRNSW, suggesting it wasn’t a microinverter based system.

The component confusion aside, there was smoke, solar was involved and it sounds like the firies dealt with the incident before any major damage occurred; bless them.

FRNSW has again urged solar buyers to do their due diligence when choosing a solar installer – and for system owners to ensure professional maintenance is kept up.

DC Isolator Switches A Common Culprit

Fire and Rescue NSW noted in a news item early this month it has seen solar panel related fires increase five-fold in the last five years, but didn’t provide any numbers. While still an uncommon occurrence in the big picture of residential PV, any increase or any incident isn’t good news.

Some of the increase could be due in part to the increasing popularity of PV in NSW. By the end of 2015, around 327,500 solar power systems had been installed in the state. By the end of June this year that figure had increased to approximately 587,000. More systems in use means an increased chance of bad stuff happening, as with any popular type of electrical product.

Much more relevant though is the hundreds of thousands of systems across the state that have been exposed to the elements for some years, which is revealing more shonky solar not built or installed to last. It’s also easy for owners to forget solar power systems need a little professional TLC from time to time to ensure everything is still operating as it should and in a safe manner.

FRNSW notes isolator switches have accounted for around half of solar power system fires in the state. What proportion of those were rooftop isolators wasn’t mentioned, but chances are many of them were.

A rooftop DC isolator is a manually operated switch situated adjacent to a solar panel array that shuts off DC current between the array and the solar inverter. It was intended as an additional safety mechanism, but the switches have caused more problems than they have solved – particularly when not installed correctly or when using poor quality components.

Solar power systems installed by a competent installer using good quality isolator switches are safe. A shroud/weather shield to help protect the isolator has also been a requirement for some time. But regardless of installation quality or whether a shroud is in place, it’s important have an inspection and system test performed every few years given the harsh conditions these little boxes and other components of a solar panel system endure.

Why Are Rooftop DC Isolators Still Used?

Many solar installers despise rooftop isolators, but they are a required part of an installation. There’s been a push to have the rooftop DC isolator requirement removed from the AS/NZS 5033 Standard for quite a while and for wall-mounted DC isolator switches to join them, instead favouring use of an isolator enclosed within the inverter.

Trivia – Australia is the only country in the world that requires a rooftop DC isolator switch be installed with a solar power system.

About Michael Bloch

Michael caught the solar power bug after purchasing components to cobble together a small off-grid PV system in 2008. He's been reporting on Australian and international solar energy news ever since.

Comments

  1. Des Scahill says

    Overall, this is ‘bad news’, and is not a ‘good look’ for the Solar PV industry in general as it provides ‘ammunition’ for those opposed to renewables to selectively use and/or exaggerate the impacts there-of.

  2. Doug Cooper says

    Even more ridiculous that you need rooftop isolator for microinverter systems.

    • I was told by an installer for micro’s that they dont need them as they mount the inverter under the panel directly to the inverter and the switches are DC anyway so that would mean you would somehow need to reach under each panel to turn it off.

  3. Chris Thaler says

    Two known incidents out of 327,000 or so installations. A very good result when one considers how many installs may have been below par from day one. Provided the D.C. cabling is enclosed within an approved solar rated conduit the likelihood of an adverse incident is low.

  4. My installer was saying that generally they dont catch fire – just smoke away however its enough to cause a ruckus.

    The whole standard for a roof mounted DC switch is somewhat crazy as emergency services wont touch the switches as they think they are dangerous and instead are instructed to throw blankets over panels if they need to access a roof and cant turn off the DC switch at the inverter end.

    The little covers they have also dont do anything as the sun comes in at an angle.

    The good news is the current crop of switches are less likely to have issues as the design and installation rules have been improved.

    They should still remove the switches from the Australian standard to bring us in line with the rest of the world – especially considering they were only introduced for safety however in fact they do the opposite.

    • Offler Crocgod says

      All fire brigades should be carrying PVStop equipment – http://www.pvstop.com.au – it’s a water-based polymer that coats the panels, cutting off the sun. Once the system is safe again, it can be just peeled off.

      • Ronald Brakels says

        That reads like an ad, but since you’re a devotee of Offler the Crocodile God, I’ll allow it. (Hey, praying to her works. I haven’t been bitten by a crocodile yet.)

  5. Michael Oke says

    When you have solar on a 2 storey roof at 30deg pitch, difficult to access why isn’t the isolator on the input to the solar inverter a better/safer place to cut power when needed?

  6. Saved lives today says

    My neighbours house caught fire from the main solar panel switch today loocated in the garage. They lost everything. The fire was in the roof before the roof caved in and set everything else on fire. Smoke alarms did not go off due to fire being in the roof. The family were out of the house & safe but only because I raised the alarm & got them out when I could see their roof was pouring out black smoke. Melbourne Victoria.

Speak Your Mind

Please keep the SolarQuotes blog constructive and useful with these 5 rules:

1. Real names are preferred - you should be happy to put your name to your comments.
2. Put down your weapons.
3. Assume positive intention.
4. If you are in the solar industry - try to get to the truth, not the sale.
5. Please stay on topic.

Please solve: 13 + 3 

Get The SolarQuotes Weekly Newsletter