Audit results for: Goliath Solar and Electrical
Audited on: 28/06/2021
Installation date28/05/2021
Installer Full NameSam Treloar
retail company nameGoliath Solar and Electrical
The Installer is also the accredited designer for this system
System description
40 x 330W Seraphim Blade Panels with a Fronius Symo 10 Three Phase Inverter
Design Steps
Cable selection based on voltage rise and drop
Production Estimates of the system
Isolator selection calculations
Calculated the correct voltages and current for labelling
String configuration voltages
The Installer completed a job safety analysis prior to commencing work
The Installer uses this JSA on most of his jobs
The installer has provided all the warranty documentation to the customer
The installer has provided the customer with a Certificate of Electrical Work
Scores
Single Line Diagram Score1.00
JSA Score1.00
Fall Arrest System Score1.00
BEFORE Roof Area Score1.00
BEFORE Inverter Area Score1.00
Racking Installed BEFORE Panels Score0.75
Installed Panels Score1.00
DC/AC Isolators Score1.00
Installed Inverters Score1.00
DC/AC Cable Run Score1.00
Warranty Documentation Score1.00
Certificate of Electrical Work Score1.00
Solar Panel Label Score1.00
Inverter Label Score1.00
Site from Far Score1.00
Voltage Rise Calculation Score1.00
Total Score /1615.75
Percentage Score98%
Photos
General comments
No AC photo present as cable was run back to back from Switchboard to Inverter
Assessor's comments
Completion - I have provided the customer with all the relevant documentation and information in accordance with the Australian Standards and CEC Guidelines. All the information provided in this form is true and correct.
Qa review table -not provided-
Single line diagram View diagram